Experimental investigation for the Secondary Failure Behavior of Partial Wall-Base Juncture Model in 1/4 PCCV

  • 1. Hyundai Institute of Construction Technology Development, Yongin (Korea, Republic of)
  • 2. Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

Description

Hyundai Institute of Construction Technology Development (HICTD) has been conducting the project on the research and development of pre-stressed concrete containment vessel (PCCV) that would be sponsored and funded by Korea Atomic Energy Research Institute (KAERI). As a part of this research, an experimental investigation is carried out to examine the secondary failure behavior of PCCV that is expected to occur at the wall-base juncture. The ultimate condition of nuclear power plant containment vessel will be happened under the internal pressure. The internal pressure induces biaxial tensile stress in the containment wall. This research purposes to experimental investigation on the secondary failure. The huge size of PCCV causes to scale down to 1/4 and designed in the partial level. To describe the wall-base juncture, point of inflection which is free flexural point must be the experimental loading point

Part of:
Proceedings of the KNS spring meeting

Additional details

Publishing Information

Publisher
KNS
Imprint Place
Daejeon (Korea, Republic of)
Imprint Title
Proceedings of the KNS spring meeting
Imprint Pagination
[1 CD-ROM]
Journal Page Range
[2 p.]

Conference

Title
2007 spring meeting of the KNS
Dates
10-11 May 2007
Place
Jeju (Korea, Republic of)

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
38113458
Subject category
S22: GENERAL STUDIES OF NUCLEAR REACTORS;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
CONTAINMENT; DESIGN; FAILURES; NUCLEAR POWER PLANTS; PRESTRESSED CONCRETE
Descriptors DEC
BUILDING MATERIALS; COMPOSITE MATERIALS; CONCRETES; MATERIALS; NUCLEAR FACILITIES; POWER PLANTS; THERMAL POWER PLANTS

Optional Information

Notes
3 refs, 6 figs, 1 tab