Published 1987 | Version v1
Report Restricted

Investigations of after-heat removal pumps

  • 1. GKSS-Forschungszentrum Geesthacht G.m.b.H., Geesthacht-Tesperhude (Germany, F.R.). Inst. fuer Anlagentechnik

Description

Parameters influencing the pump performance were analysed during stationary and instationary conditions of an original DWR-heat removal pump, which was equipped with special measurement devices. The most important results will be presented by the following: 1) air addition deteriorates pump performance; 2) increasing system temperatures improve cavitation behaviour; 3) instationary tests lead to hysteresis phenomena; 4) pump performance was good within the tested parameter region. With 94 figs

Abstract (German)

Mit den Versuchen an einer originalen Nachkuehlpumpe einer DWR-Anlage, die messtechnisch besonders ausgestattet war, wurden einzelne, das Betriebsverhalten beeinflussende Parameter unter stationaeren und instationaeren Randbedingungen analysiert. Als wichtigste Ergebnisse werden festgehalten, dass 1) Luftzugaben das Betriebsverhalten der Pumpe verschlechtern; 2) hoehere Systemtemperaturen das Kavitaionsverhalten verbessern; 3) instationaere Versuche zu Hysteresiserscheinungen fuehren; 4) das Betriebsverhalten im untersuchten Bereich gut war. With 94 figs

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Additional titles

Subtitle (English)
Final report
Original title (German)
Nachkuehlpumpen-Untersuchungen
Original subtitle (German)
Abschlussbericht.

Publishing Information

Imprint Pagination
170 p.
Report number
GKSS--86/E/60