Interim reliability evaluation program: analysis of the Arkansas Nuclear One. Unit 1 nuclear power plant. Volume 2 of 2
Description
Appendices are presented concerning systemic event tree analysis; analysis of the ANO-1 front-line and support systems; high pressure injection/high pressure recirculation system; low pressure injection/low pressure recirculation system; core flood system; reactor building spray system; emergency feedwater system; reactor building cooling system; reactor protection system; power conversion system; engineered safeguards activation system; service water system; class 1E AC power system; 125 volt DC system; battery and switchgear emergency cooling system; emergency feedwater initiation and control system; human interface system; sequence quantification; and supporting calculations
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS, PC A99/MF A01 as DE83000708.
Files
Additional details
Publishing Information
- Imprint Pagination
- 1108 p.
- Report number
- NUREG/CR--2787
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 14742093
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY; S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- ARKANSAS-1 REACTOR; AUXILIARY WATER SYSTEMS; CONTAINMENT SPRAY SYSTEMS; ECCS; FAILURE MODE ANALYSIS; FAULT TREE ANALYSIS; FEEDWATER; HUMAN FACTORS; PERFORMANCE; POWER SUPPLIES; REACTOR ACCIDENTS; REACTOR PROTECTION SYSTEMS; RELIABILITY; SAFETY ENGINEERING
- Descriptors DEC
- ACCIDENTS; CONTAINMENT; CONTAINMENT SYSTEMS; ELECTRONIC EQUIPMENT; ENRICHED URANIUM REACTORS; EQUIPMENT; HYDROGEN COMPOUNDS; OXYGEN COMPOUNDS; POWER REACTORS; PWR TYPE REACTORS; REACTORS; SYSTEM FAILURE ANALYSIS; SYSTEMS ANALYSIS; WATER; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Secondary number(s)
- SAND--82-0978.