Published December 2018 | Version v1
Journal article

Shear wave elasticity imaging for residual endoleak and thrombus characterisation after endoleak embolisation following endovascular aneurysm repair: a canine animal study

Description

Background

To evaluate residual endoleak and thrombus organisation with shear wave imaging (SWI) after endoleak embolisation through an animal study.

Methods

This prospective experimental study involved eight dogs with creation of 16 iliac aneurysms and type I endoleak after endovascular aneurysm repair (EVAR). Embolisation agents were injected into the sac to seal endoleak. SWI and colour flow Doppler ultrasound (DUS) were performed at implantation, one week, and one and three months after implantation; for three dogs, SWI and DUS were also performed six months after implantation. Digital subtraction angiography and contrast-enhanced computed tomography were performed at sacrifice. Macroscopic and histopathological analyses were processed to identify regions of interest (ROIs) for endoleak, fresh thrombus, organised thrombus and embolisation agent, where SWI elasticity moduli were compared.

Results

At sacrifice, nine aneurysms had residual endoleak, while seven were sealed. Ten had a fresh and 15 had an organised thrombus. SWI was able to detect all endoleaks, including two cases undetected with DUS. Elasticity moduli of 0.2 kPa ± 0.1 kPa (mean ± SD), 9.5 kPa ± 3.3 kPa, 48.1 kPa ± 21.3 kPa and 44.9 kPa ± 23.7 kPa were found in the ROIs positioned in endoleaks, fresh thrombi, organised thrombi and embolisation agent, respectively. Elasticity values of endoleak and fresh thrombus were lower than those of organised thrombi and embolisation agent (p < 0.001). Stiffness of fresh thrombus at one week (8.7 kPa ± 3.6 kPa) increased at three months (30.2 kPa ± 13.8 kPa), indicating thrombus maturation (p < 0.001).

Conclusions

In a dog model of iliac EVAR, SWI was able to identify endoleak, thrombus maturation and embolising agents after endoleak embolisation.

Additional details

Identifiers

Publishing Information

Journal Title
European Radiology Experimental
Journal Volume
2
Journal Issue
1
Journal Page Range
p. 1-9
ISSN
2509-9280

INIS

Country of Publication
Switzerland
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
51016054
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
BIOMEDICAL RADIOGRAPHY; BLOOD VESSELS; COMPUTERIZED TOMOGRAPHY; DOGS; ULTRASONOGRAPHY
Descriptors DEC
ANIMALS; BODY; CARDIOVASCULAR SYSTEM; DIAGNOSTIC TECHNIQUES; MAMMALS; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; TOMOGRAPHY; VERTEBRATES

Optional Information

Copyright
Copyright (c) 2018 The Author(s)