A new scheme of global feature management improved the performance and stability of radiomics model. A study based on CT images of acute brainstem infarction
- 1. Department of Psychiatry, Zhenjiang Mental Health Center, Zhenjiang (China)
- 2. Department of Radiology, Affiliated Hospital of Jiangsu University, Zhenjiang (China)
- 3. Neuroimaging Laboratory, Medical College of Jiangsu University, Zhenjiang (China)
- 4. Department of Radiology, Zhongda Affiliated Hospital of Southeast University, Nanjing (China)
Description
The performance and stability of radiomics model caused by dimension reduction remain being confronted with major challenges. In this study, we aimed to propose a new scheme of global feature management independent of dimension reduction to improve it. The non-contrast computed tomography (NCCT) images of acute brainstem infarction (ABI) from two medical centers were used as test and validation sets. A new scheme was constructed based on global feature management, and the traditional scheme dependent on dimension reduction was used as control. The radiomic features of NCCT images were extracted in Matlab R2013a. The performance of prediction model was evaluated by the generalized linear model (GLM) and multivariate logistic regression. And, the stability of radiomics model was evaluated with the difference of area under curve (AUC) between the test and validation sets. Compared with the traditional scheme, the new scheme presented a similar detection performance (AUC: 0.875 vs. 0.883), yet a better performance in predicting prognosis (AUC: 0.864, OR = 0.917, p = 0.021 vs. AUC:0.806, OR = 0.972, p = 0.007). All these results were well verified in an independent validation set. Moreover, the new scheme showed stronger stability in both the detection model (ΔAUC: 0.013 vs. 0.039) and prediction model (ΔAUC = 0.004 vs. 0.044). Although there might be several limitations, this study proved that the scheme of global feature management independent of dimension reduction could be a powerful supplement to the radiomics methodology. The new scheme (S) presented similar detection performances for ABI with the traditional scheme. A better predictive performance for END was found in the new scheme (S) compared with the traditional scheme. Stronger model stability was found in both the detection and prediction models based on the new scheme.
Availability note (English)
Available from: http://dx.doi.org/10.1007/s00330-022-08659-wAdditional details
Identifiers
Publishing Information
- Journal Title
- European Radiology (Internet)
- Journal Volume
- 32
- Journal Issue
- 8
- Journal Page Range
- p. 5508-5516
- ISSN
- 1432-1084
- CODEN
- EURAE3
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 53092815
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BLOOD CIRCULATION; BRAIN; COMPARATIVE EVALUATIONS; COMPUTERIZED TOMOGRAPHY; DETECTION; ISCHEMIA; MULTIVARIATE ANALYSIS; PERFORMANCE; RADIOMICS; REGRESSION ANALYSIS; SURVIVAL CURVES; VALIDATION
- Descriptors DEC
- ANEMIAS; BODY; CARDIOVASCULAR DISEASES; CENTRAL NERVOUS SYSTEM; DIAGNOSTIC TECHNIQUES; DISEASES; EVALUATION; HEMIC DISEASES; MATHEMATICS; MEDICINE; NERVOUS SYSTEM; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; STATISTICS; SYMPTOMS; TESTING; TOMOGRAPHY; VASCULAR DISEASES