Published June 7, 2011 | Version v1
Journal article

A GPU-based finite-size pencil beam algorithm with 3D-density correction for radiotherapy dose calculation

  • 1. Center for Advanced Radiotherapy Technologies and Department of Radiation Oncology, University of California San Diego, La Jolla, CA 92037-0843 (United States)
  • 2. University Hospital Giessen and Marburg, Department of Radiotherapy and Radiation Oncology, Particle Therapy Center Marburg, 34045 Marburg (Germany)
  • 3. Department of Radiation Oncology, Fox Chase Cancer Center, 333 Cottman Avenue, Philadelphia, PA 19111 (United States)

Description

Targeting at the development of an accurate and efficient dose calculation engine for online adaptive radiotherapy, we have implemented a finite-size pencil beam (FSPB) algorithm with a 3D-density correction method on graphics processing unit (GPU). This new GPU-based dose engine is built on our previously published ultrafast FSPB computational framework (Gu et al 2009 Phys. Med. Biol. 54 6287-97). Dosimetric evaluations against Monte Carlo dose calculations are conducted on ten IMRT treatment plans (five head-and-neck cases and five lung cases). For all cases, there is improvement with the 3D-density correction over the conventional FSPB algorithm and for most cases the improvement is significant. Regarding the efficiency, because of the appropriate arrangement of memory access and the usage of GPU intrinsic functions, the dose calculation for an IMRT plan can be accomplished well within 1 s (except for one case) with this new GPU-based FSPB algorithm. Compared to the previous GPU-based FSPB algorithm without 3D-density correction, this new algorithm, though slightly sacrificing the computational efficiency (∼5-15% lower), has significantly improved the dose calculation accuracy, making it more suitable for online IMRT replanning.

Availability note (English)

Available from http://dx.doi.org/10.1088/0031-9155/56/11/010

Additional details

Identifiers

DOI
10.1088/0031-9155/56/11/010;
PII
S0031-9155(11)86563-2;

Publishing Information

Journal Title
Physics in Medicine and Biology
Journal Volume
56
Journal Issue
11
Journal Page Range
p. 3337-3350
ISSN
0031-9155
CODEN
PHMBA7

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
43022834
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
ACCURACY; ALGORITHMS; BEAMS; CORRECTIONS; DENSITY; DOSES; EFFICIENCY; ENGINES; EVALUATION; HEAD; LUNGS; MONTE CARLO METHOD; NECK; RADIOTHERAPY
Descriptors DEC
BODY; CALCULATION METHODS; MATHEMATICAL LOGIC; MEDICINE; NUCLEAR MEDICINE; ORGANS; PHYSICAL PROPERTIES; RADIOLOGY; RESPIRATORY SYSTEM; THERAPY