Published February 2008 | Version v1
Journal article

Data filtering in the readout of the CMS Electromagnetic Calorimeter

  • 1. LIP, Av. Elias Garcia 14, 1o 1000-149 Lisbon (Portugal)
  • 2. DAPNIA, CEA, Saclay - 91191 Gif sur Yvette (France)
  • 3. LLR, CNRS-IN2P3, Ecole Polytechnique, 91128 Palaiseau (France)

Description

For an efficient data taking, the Electromagnetic Calorimeter data of the CMS experiment must be limited to 10% of the full event size (1MB). Other requirements limit the average data size to 2kB per data acquisition link. These conditions imply a reduction factor of close to twenty on the data collected. The data filtering in the readout of the Electromagnetic Calorimeter detector is discussed. Test beam data are used to study the digital filtering applied in the readout channels and a full detector simulation allows to estimate the energy thresholds to achieve the desired data suppression factor

Availability note (English)

Available from http://dx.doi.org/10.1088/1748-0221/3/02/P02011

Additional details

Publishing Information

Journal Title
Journal of Instrumentation
Journal Volume
3
Journal Issue
02
Journal Page Range
p. P02011
ISSN
1748-0221

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
39108673
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Descriptors DEI
BEAMS; DATA ACQUISITION; DIGITAL FILTERS; READOUT SYSTEMS; SHOWER COUNTERS; SIMULATION
Descriptors DEC
MEASURING INSTRUMENTS; RADIATION DETECTORS