Research and design of the moving system for the cobalt-60 industrial irradiator VINAGA2
Creators
- 1. Research and Development Center for Radiation Technology, Ho Chi Minh City (Viet Nam)
Description
On the way of localization of Cobalt-60 industrial irradiators, Research and Development Center for Radiation Technology (VINAGAMMA) has successfully designed and manufactured the first version of Co-60 industrial irradiator, VINAGA1. The second version of Co-60 industrial irradiator has been studied and designed by VINAGAMMA in the frame of the scientific project No. DTCB.02/15/TTNCTK. The main system of a Co-60 industrial irradiator is a mechanical system inside an irradiation room namely a tote box moving system. This report presents the tote box moving system of VINAGA2 designed by VINAGAMMA. The tote box moving system contains 52 tote boxes with the dimensions of 50 cm (w) × 70 cm (l) × 150 cm (h) that are moving around the source racks in the manner of 4 passes and 2 levels. The irradiator VINAGA2 with this tote box moving system has good specifications: The minimum time of an irradiation cycle is 1 h 20 min. and the dose uniformity ratio (DUR) at the product densities of 0.1 g/cm3 and 0.5 g/cm3 is 1.4 and 1.8, respectively. Radiation energy utilization efficiency at the product densities of 0.1 g/cm3 and 0.5 g/cm3 is 19.7% and 48.8%, respectively. These specifications meet the requirements for a multi-purpose Co-60 industrial irradiator and the present irradiation requirements in Vietnam. (author)
Files
49044531.pdf
Files
(572.1 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:db1711f79a47689680b8b06a454f39f0
|
572.1 kB | Preview Download |
Additional details
Publishing Information
- Imprint Title
- The VINATOM - Annual Report for 2016
- Imprint Pagination
- 253 p.
- Journal Page Range
- p. 57-64
- Report number
- VINATOM-AR--16
INIS
- Country of Publication
- Viet Nam
- Country of Input or Organization
- Viet Nam
- INIS RN
- 49044531
- Subject category
- S42: ENGINEERING;
- Descriptors DEI
- ABSORBED RADIATION DOSES; CHAIN CONVEYORS; DESIGN; EFFICIENCY; FABRICATION; IRRADIATION; IRRADIATION PLANTS; RADIATION DOSE DISTRIBUTIONS; SPECIFICATIONS; VIET NAM
- Descriptors DEC
- ASIA; CONVEYORS; DEVELOPING COUNTRIES; DOSES; EQUIPMENT; HAULAGE EQUIPMENT; MATERIALS HANDLING EQUIPMENT; NUCLEAR FACILITIES; RADIATION DOSES
Optional Information
- Notes
- 8 refs, 4 tabs, 4 figs
- Secondary number(s)
- VINATOM-AR--16-06