Film cooling characteristics with sunk or lifted upstream wall
Description
Film cooling characteristics has been investigated numerically with the aid of FLUENT software for the sunk or the lifted upstream wall from the slot injection exit. In this study, with the fixed blowing ratio of 1 and the fixed coolant injection angle of 30 .deg., the downstream flow field and the downstream temperature field were examined in terms of velocity vector, turbulent kinetic energy, temperature contours, and downstream wall temperature. Upstream wall was sunk or lifted from 1d to 5d(d=slot width). The result shows that the up-1d upstream wall has the best film cooling performance. This is due to the fact that the up-1d upstream wall configuration reduces velocity gradient just enough to minimize the turbulent mixing between the mainstream and the coolant just off the slot exit
Additional details
Publishing Information
- Publisher
- KSME
- Imprint Place
- Seoul (Korea, Republic of)
- Imprint Title
- Proceedings of the KSME 2001 spring annual meeting D
- Imprint Pagination
- 1019 p.
- Journal Page Range
- p. 377-381
Conference
- Title
- KSME 2001 spring annual meeting D
- Dates
- 27-29 Jun 2001
- Place
- Cheju (Korea, Republic of)
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 36022298
- Subject category
- S42: ENGINEERING;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- COOLANTS; FILM COOLING; INJECTION; MIXING; NUMERICAL ANALYSIS; PERFORMANCE; TEMPERATURE DISTRIBUTION; TURBULENCE; VELOCITY
- Descriptors DEC
- COOLING; INTAKE; MATHEMATICS
Optional Information
- Notes
- 6 refs, 9 figs