Published October 1976
| Version v1
Report
Restricted
Westinghouse ECCS: four loop plant (17 x 17) sensitivity studies with upper head fluid temperature at T/sub hot/
Description
The report presents the results of analyses performed for a representative four-loop plant with 17 x 17 fuel design which show the effects of increased upper head fluid temperature on calculated ECCS performance during a LOCA. These analyses use the October, 1975 version of the Westinghouse ECCS Evaluation Model
Availability note (English)
MF available from INIS under the Report Number.
Files
Additional details
Additional titles
- Augmented title (English)
- PWR
Publishing Information
- Imprint Pagination
- v p.
- Report number
- WCAP--8865
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 8318425
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY; S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- ECCS; LOSS OF COOLANT; MATHEMATICAL MODELS; PERFORMANCE; PWR TYPE REACTORS; REACTOR SAFETY
- Descriptors DEC
- ACCIDENTS; REACTOR ACCIDENTS; REACTOR PROTECTION SYSTEMS; REACTORS; SAFETY; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Notes
- Westinghouse Electric Corp., Pittsburgh, PA.