Published December 1991
| Version v1
Journal article
Improved dose homogeneity in the breast using tissue compensators
- 1. Royal Marsden Hospital, Sutton (United Kingdom)
- 2. Institute of Cancer Research, Sutton (United Kingdom). Surrey Branch
Description
The improvements achievable by introducing individual tissue compensators in photon therapy of the breast were assessed. In 37 patients the dose ranged from+15 to -10% of the mid target dose using combinations of wedge filters and beam weights alone. With a tissue compensator the dose ranged from +4 to -11% provided that allowance was made for lung attenuation. A megavoltage imaging system is a potential source of the X-ray transmission data which can provide a basis for the calculation of thickness of the compensator. (author). 10 refs.; 4 figs
Additional details
Publishing Information
- Journal Title
- Radiotherapy and Oncology
- Journal Volume
- 22
- Journal Issue
- 4
- Series
- Radiother. Oncol.
- Journal Page Range
- 248-251
- ISSN
- 0167-8140
- CODEN
- RAOND
Conference
- Title
- A Consensus Meeting on Quality Assurance in Conservative Treatment of Early Breast Cancer.
- Dates
- 13-14 Dec 1990.
- Place
- Tuebingen (Germany).
INIS
- Country of Publication
- Ireland
- Country of Input or Organization
- Netherlands
- INIS RN
- 23058729
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- MAMMARY GLANDS; NEOPLASMS; RADIATION DOSES; THERAPY
- Descriptors DEC
- BODY; DISEASES; GLANDS; MEDICINE; ORGANS
Optional Information
- Notes
- This work was supported by the Cancer Research Campaign (United Kingdom).