Performance figures and images from the therascan 3128 positron emission tomograph
- 1. Atomic Energy of Canada Limited, Medical Products Division 413 March Road, P.O. Box 13500, Kanata, Ontario CANADA K2K 1X8
Description
The THERASCAN 3128 system has been designed to study cerebral function using positron emission tomography (PET) methods. Two rings of bismuth germanate (BGO) detectors define three image planes per scan. For the low resolution mode image resolution is 19 mm x 19 mm x 20 mm (axial) and the direct slice sensitivity for true coincidences is 88 kcps/(μCi.cm-3). In the high resolution mode image resolution is 12 mm x 12 mm x 12 mm with a sensitivity of 33 kcps/(μCi.cm-3). Deconvolution methods used to remove scattered events have been verified by repeated imaging of a phantom designed to provide a wide variation in contrast with time. Clinical images from 18F-2-fluorodeoxyglucose (FDG) and 15O studies are presented as practical examples of system performance and to illustrate the useful information obtained from coronal/sagittal sectioning of closely spaced transverse images
Additional details
Publishing Information
- Journal Title
- IEEE Trans. Nucl. Sci.
- Journal Volume
- 31
- Journal Issue
- 1
- Series
- IEEE Trans. Nucl. Sci.
- Journal Page Range
- 640-644
- ISSN
- 0018-9499
Conference
- Title
- Nuclear science symposium.
- Dates
- 19-21 Oct 1983.
- Place
- San Francisco, CA (USA).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 15068181
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; S07: ISOTOPES AND RADIATION SOURCES;
- Resource subtype / Literary indicator
- Conference, Numerical Data
- Descriptors DEI
- ANTIMETABOLITES; BISMUTH GERMANATES; BRAIN; EXPERIMENTAL DATA; FLUORINE 18; GLUCOSE; IMAGE PROCESSING; ORGANIC FLUORINE COMPOUNDS; OXYGEN 15; PERFORMANCE; PHANTOMS; POSITRON CAMERAS; POSITRON COMPUTED TOMOGRAPHY; RADIOISOTOPE SCANNING; SENSITIVITY; SOLID SCINTILLATION DETECTORS; SPATIAL RESOLUTION; SPECIFICATIONS
- Descriptors DEC
- ALDEHYDES; BETA DECAY RADIOISOTOPES; BETA-PLUS DECAY RADIOISOTOPES; BISMUTH COMPOUNDS; BODY; CAMERAS; CARBOHYDRATES; CENTRAL NERVOUS SYSTEM; COMPUTERIZED TOMOGRAPHY; COUNTING TECHNIQUES; DATA; DIAGNOSTIC TECHNIQUES; DRUGS; EMISSION COMPUTED TOMOGRAPHY; EVEN-ODD NUCLEI; FLUORINE ISOTOPES; GAMMA CAMERAS; GERMANATES; GERMANIUM COMPOUNDS; HEXOSES; HOURS LIVING RADIOISOTOPES; INFORMATION; ISOTOPES; LIGHT NUCLEI; MEASURING INSTRUMENTS; MINUTES LIVING RADIOISOTOPES; MOCKUP; MONOSACCHARIDES; NERVOUS SYSTEM; NUCLEI; NUMERICAL DATA; ODD-ODD NUCLEI; ORGANIC COMPOUNDS; ORGANIC HALOGEN COMPOUNDS; ORGANS; OXYGEN COMPOUNDS; OXYGEN ISOTOPES; RADIATION DETECTORS; RADIOISOTOPES; RESOLUTION; SACCHARIDES; SCINTILLATION COUNTERS; STRUCTURAL MODELS; TOMOGRAPHY
Optional Information
- Secondary number(s)
- CONF-831015--.