Published 1975 | Version v1
Report

Study on stability period of the synchronization system for 2 GeV electron linac

Description

Methods and results are presented of studies of a stable period of LUE-2 GeV accelerator synchronizing pulses. Synchronizing pulses are shown to be connected with a starting voltage phase with a relative accuracy not less than +-0.77.10-4. The period instability is accounted for by instabilities of the starting voltage and results in the instability of the output parameters of the accelerated bunch

Additional details

Additional titles

Original title (Russian)
Исследование стабильности периода системы синхронизации ускорителя LUEh-2 GeV

Publishing Information

Imprint Title
Nuclear science and engineering problems
Journal Issue
no. 1(5
Series
Avtomatizatsiya i matematicheskoe obespechenie fizicheskogo ehksperimenta.
Journal Page Range
p. 39-40.
Report number
KFTI--75-27

INIS

Country of Publication
USSR
Country of Input or Organization
USSR
INIS RN
8338025
Subject category
S43: PARTICLE ACCELERATORS;
Descriptors DEI
BEAM CURRENTS; DIAGRAMS; GEV RANGE 01-10; LINEAR ACCELERATORS; STABILITY; TIME MEASUREMENT; TIMING CIRCUITS
Descriptors DEC
ACCELERATORS; CURRENTS; CYCLIC ACCELERATORS; ELECTRONIC CIRCUITS; ENERGY RANGE; GEV RANGE

Optional Information

Notes
Imprint:3 refs.; 3 figs. ;Voprosy atomnoj nauki i tekhniki.