Published December 1995 | Version v1
Journal article

Development of the double-wall-tube steam generator. Evaluation of inner tube leak detection system

  • 1. Power Reactor and Nuclear Fuel Development Corp., Oarai, Ibaraki (Japan). Oarai Engineering Center

Description

A double-wall-tube steam generator (DWT-SG) is considered to have possibility of eliminating a secondary heat transport system to realize a reliable and simplified FBR plant. Thus, basic tests for inner/outer tube leak detection and prototypical leak tests by use of the 1MWt DWT-SG model have been performed to evaluate the feasibility of DWT-SG. Their results demonstrated that the inner leak detection system can definitely detect a steam leak from an inner tube flaw. Analyses of the inner tube leak and detection behavior obtained in the 1MWt DWT-SG test enabled to estimate the performance of the inner tube detection system of the commercial DWT-SG system. (author)

Additional details

Publishing Information

Journal Title
Donen Giho
Journal Issue
no.96
Journal Page Range
p. 38-43.
ISSN
0289-6605
CODEN
DOGIEL