Published December 1995
| Version v1
Journal article
Development of the double-wall-tube steam generator. Evaluation of inner tube leak detection system
Creators
- 1. Power Reactor and Nuclear Fuel Development Corp., Oarai, Ibaraki (Japan). Oarai Engineering Center
Description
A double-wall-tube steam generator (DWT-SG) is considered to have possibility of eliminating a secondary heat transport system to realize a reliable and simplified FBR plant. Thus, basic tests for inner/outer tube leak detection and prototypical leak tests by use of the 1MWt DWT-SG model have been performed to evaluate the feasibility of DWT-SG. Their results demonstrated that the inner leak detection system can definitely detect a steam leak from an inner tube flaw. Analyses of the inner tube leak and detection behavior obtained in the 1MWt DWT-SG test enabled to estimate the performance of the inner tube detection system of the commercial DWT-SG system. (author)
Additional details
Publishing Information
- Journal Title
- Donen Giho
- Journal Issue
- no.96
- Journal Page Range
- p. 38-43.
- ISSN
- 0289-6605
- CODEN
- DOGIEL
INIS
- Country of Publication
- Japan
- Country of Input or Organization
- Japan
- INIS RN
- 27045348
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- EVALUATION; FBR TYPE REACTORS; FLOW RATE; HYGROMETRY; LEAK TESTING; OXIDATION; SCALE MODELS; SIMULATION; STEAM GENERATORS; TIME DELAY; TUBES
- Descriptors DEC
- BOILERS; BREEDER REACTORS; CHEMICAL REACTIONS; EPITHERMAL REACTORS; FAST REACTORS; REACTORS; STRUCTURAL MODELS; TESTING; VAPOR GENERATORS