A picosecond bunching system at the Munich MP-tandem accelerator
- 1. Technische Univ. Muenchen, Garching (Germany, F.R.). Physik-Dept.
Description
A picosecond bunching system was installed at the Munich MP-tandem accelerator. The resonator of the buncher consists of a sphere (diameter 1.65 m) and two axial cones with a total shunt impedance of 14 MΩ and a Q-factor of 2.8x104. The performance of the system was tested in time-of-flight experiments with heavy ions. Time resolutions of 75 ps (fwhm) for 18O, 95 ps (fwhm) for 32S and 110 ps (fwhm) for 58Ni were achieved with Si surface barrier detectors. (Auth.)
Additional details
Publishing Information
- Journal Title
- Nucl. Instrum. Methods
- Journal Volume
- 164
- Journal Issue
- 2
- Series
- Nucl. Instrum. Methods.
- Journal Page Range
- 219-224
- ISSN
- 0029-554X
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- Netherlands
- INIS RN
- 11505631
- Subject category
- S43: PARTICLE ACCELERATORS;
- Descriptors DEI
- BEAM BUNCHING; CONICAL CONFIGURATION; CONTROL SYSTEMS; CRNL MP TANDEM ACCELERATOR; NICKEL 58 BEAMS; OXYGEN 18 BEAMS; PERFORMANCE; PULSE CIRCUITS; SPECIFICATIONS; SPHERICAL CONFIGURATION; SULFUR 32 BEAMS; TIME RESOLUTION; TIME-OF-FLIGHT METHOD
- Descriptors DEC
- ACCELERATORS; BEAM DYNAMICS; BEAMS; CONFIGURATION; ELECTRONIC CIRCUITS; ELECTROSTATIC ACCELERATORS; ION BEAMS; RESOLUTION; TIMING PROPERTIES; VAN DE GRAAFF ACCELERATORS