Published October 2008 | Version v1
Journal article

Overview of equilibrium reconstruction on DIII-D using new measurements from an expanded motional Stark effect diagnostic

  • 1. Lawrence Livermore National Laboratory, 7000 East Ave., Livermore, California 94550 (United States)
  • 2. General Atomics, P.O. Box 85608, San Diego, California 92186-5608 (United States)

Description

Motional Stark effect (MSE) measurements constrain equilibrium reconstruction of DIII-D tokamak plasmas using the equilibrium code EFIT. In 2007, two new MSE arrays were brought online, bringing the system to three core arrays, two edge arrays, and 64 total channels. We present the first EFIT reconstructions using this expanded system. Safety factor and ER profiles produced by fitting to data from the two new arrays and one of the other three agree well with independent measurements. Comparison of the data from the three arrays that view the core shows that one of the older arrays is inconsistent with the other two unless the measured calibration factors for this array are adjusted. The required adjustments depend on the toroidal field and plasma current direction, and on still other uncertain factors that change as the plasma evolves. We discuss possible sources of calibration error for this array.

Additional details

Identifiers

Publishing Information

Journal Title
Review of Scientific Instruments
Journal Volume
79
Journal Issue
10
Journal Page Range
p. 10F518-10F518.4
ISSN
0034-6748
CODEN
RSINAK

Conference

Title
17. topical conference on high-temperature plasma diagnostics
Acronym
HTPD08
Dates
11-15 May 2008
Place
Albuquerque, NM (United States)

INIS

Country of Publication
United States
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
41016162
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
CALIBRATION; COMPARATIVE EVALUATIONS; DOUBLET-3 DEVICE; ELECTRIC CURRENTS; EQUILIBRIUM; PLASMA; PLASMA DIAGNOSTICS; STARK EFFECT
Descriptors DEC
CLOSED PLASMA DEVICES; CURRENTS; EVALUATION; THERMONUCLEAR DEVICES; TOKAMAK DEVICES

Optional Information

Notes