Published November 1975
| Version v1
Journal article
Secondary radiation from a spherical tissue-equivalent phantom irradiated with 60Co gamma radiation and 6 MV X-rays
Description
The angular dependence and the dependence on the phantom mass of the secondary exposure rate from spherical tissue-equivalent phantoms irradiated with 60Co gamma radiation and 6 MV X-rays have been investigated both by measurement and by calculation using the Monte Carlo method and approximate methods. A nonlinear dependence on the phantom mass was found. Calculation of the differential photon fluence was also made. These measurements and calculations can be used when calculating the required barrier thickness for walls which are not hit by primary radiation. (author)
Additional details
Identifiers
Publishing Information
- Journal Title
- Physics in Medicine & Biology
- Journal Volume
- 20
- Journal Issue
- 6
- Series
- Phys. Med. Biol.
- Journal Page Range
- 963-973
- ISSN
- 0031-9155
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- United Kingdom
- INIS RN
- 7233627
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Descriptors DEI
- DOSE RATES; GAMMA RADIATION; IRRADIATION; MASS; PATIENTS; PHANTOMS; PHOTON EMISSION; PLANNING; RADIATION DOSES; RADIATION PROTECTION; RADIOTHERAPY; SECONDARY EMISSION; SHIELDING; SPATIAL DOSE DISTRIBUTIONS; THICKNESS; X RADIATION
- Descriptors DEC
- DIMENSIONS; ELECTROMAGNETIC RADIATION; EMISSION; IONIZING RADIATIONS; MEDICINE; MOCKUP; RADIATION DOSE DISTRIBUTIONS; RADIATIONS; STRUCTURAL MODELS; THERAPY