Published March 1984 | Version v1
Report Open

Accuracy and precision of dosimetry required for radiotherapy and atomic, molecular and nuclear data affected on accuracy

  • 1. Japanese Foundation for Cancer Research, Tokyo. Cancer Inst.

Description

The occurrence of normal tissue complications and probability of tumor control are steep functions of absorbed dose. It has been recommended, therefore, that the delivery of the dose to the patient should be performed with a precision better than +-2% and an overall uncertainty less than +-5%. This paper describes the sequence of dosimetry procedures to deliver the absorbed dose to the patient and the method of determining absorbed dose for x-ray, electron and neutron therapy. The uncertainties of physical parameters involved in dosimetry are discussed. (author)

Files

16038687.pdf

Files (472.2 kB)

Name Size Download all
md5:485d2ed7eedbde823886dbb3a2c91c27
472.2 kB Preview Download

Additional details

Publishing Information

Imprint Title
Proceedings of the 1983 seminar on nuclear data
Imprint Pagination
434 p.
Journal Page Range
p. 231-250.
Report number
JAERI-M--84-010

Conference

Title
1983 seminar on nuclear data.
Dates
30 Nov - 1 Dec 1983.
Place
Tokai, Ibaraki (Japan).

Optional Information