Description
Oropharyngeal cancer patients are treated with the two-step intensity modulated radiotherapy (IMRT) in our institution. Deformable image registration (DIR) is a critical technic in adaptive radiotherapy (ART) for propagating contours between planning computerized tomography (CT) images and treatment CT/cone-beam CT (CBCT) images to account for organ deformation for treatment re-planning
Additional details
Publishing Information
- Journal Title
- Journal of Medical Physics
- Journal Volume
- 42
- Journal Issue
- suppl.1
- Journal Page Range
- p. 146-147
- CODEN
- JMPHFE
Conference
- Title
- 17. Asia-Oceania Congress of Medical Physics; 38. annual conference of Association of Medical Physicists of India
- Acronym
- AOCMP-AMPICON 2017
- Dates
- 4-7 Nov 2017
- Place
- Jaipur (India)
INIS
- Country of Publication
- India
- Country of Input or Organization
- India
- INIS RN
- 49051763
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- BRAIN; COMPUTERIZED TOMOGRAPHY; NEOPLASMS; RADIATION DOSE DISTRIBUTIONS; RADIATION DOSES; RADIOTHERAPY; SPINAL CORD
- Descriptors DEC
- BODY; CENTRAL NERVOUS SYSTEM; DIAGNOSTIC TECHNIQUES; DISEASES; DOSES; MEDICINE; NERVOUS SYSTEM; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; THERAPY; TOMOGRAPHY