Published February 1984
| Version v1
Report
Restricted
The ECE diagnostic system on TEXTOR
Description
A heterodyne millimeter wave radiometer was built to record simultaneously the first ordinary and second extraordinary wave of ECE emitted from the same point in the plasma. The optical depth of the TEXTOR plasma was calculated for typical TEXTOR parameters. The accessibility of ECE-radiation was considered. First experimental results from TEXTOR are presented. The electron temperature on axis of the TEXTOR plasma is routinely monitored from ECE intensity measurements. An instantaneous half electron temperature profile and its development in time are shown. Internal plasma disruptions are visualized by a sawtooth modulation of the ECE intensity. Also MHD-activity in the plasma is reflected in the ECE. (orig.)
Availability note (English)
MF available from INIS under the Report Number.
Files
Additional details
Publishing Information
- Imprint Pagination
- 27 p.
- Report number
- Juel--1898
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 15062698
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
- Descriptors DEI
- CYCLOTRON HARMONICS; CYCLOTRON RADIATION; ELECTRON CYCLOTRON-RESONANCE; ELECTRON TEMPERATURE; OPTICALLY THICK PLASMA; PLASMA DIAGNOSTICS; PLASMA INSTABILITY; RADIOMETERS; TEXTOR TOKAMAK
- Descriptors DEC
- BREMSSTRAHLUNG; CLOSED PLASMA DEVICES; CYCLOTRON RESONANCE; ELECTROMAGNETIC RADIATION; HARMONICS; INSTABILITY; MEASURING INSTRUMENTS; OSCILLATIONS; PLASMA; RADIATION DETECTORS; RADIATIONS; RESONANCE; THERMONUCLEAR DEVICES; TOKAMAK DEVICES
Optional Information
- Notes
- With 17 figs.