Published July 1994 | Version v1
Report

Measurement of transverse geometric moments of the TRIUMF beam with a multistrip monitor

Description

A multistrip gap monitor has been built and tested in a TRIUMF beam line. Wall currents, induced by the beam, are carried along eight conducting strips arranged circumferentially around a non-conducting section of beam pipe. A gap in each strip is bridged by a resistor. The eight voltages may be analyzed by applying a circumferential Fourier transform (CFT) to give dipole (position) and quadrupole (aspect) moments of the beam. The device bandwidth (2 GHz) is sufficient to show variations in these moments along the beam bunch. (author)

Availability note (English)

Available from TRIUMF, Vancouver, British Columbia (Canada).

Additional details

Publishing Information

Imprint Pagination
3 p.
Report number
TRI-PP--94-61

Conference

Title
4. European particle accelerator conference. EPAC 94
Dates
27 Jun - 1 Jul 1994
Place
London (United Kingdom)

INIS

Country of Publication
Canada
Country of Input or Organization
Canada
INIS RN
37013121
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
BEAM MONITORING; BEAM MONITORS; BEAM POSITION; DIPOLE MOMENTS; FOURIER TRANSFORMATION; QUADRUPOLE MOMENTS; TRIUMF CYCLOTRON
Descriptors DEC
ACCELERATORS; CYCLIC ACCELERATORS; CYCLOTRONS; INTEGRAL TRANSFORMATIONS; ISOCHRONOUS CYCLOTRONS; MEASURING INSTRUMENTS; MONITORING; MONITORS; TRANSFORMATIONS

Optional Information

Notes
6 refs., 2 tabs., 6 figs.