Published December 2013 | Version v1
Journal article

Dynamic analysis for U-tube steam generator of AP1000 based on Matlab

  • 1. Guangdong Power Test and Research Insitute, Guangzhou (China)
  • 2. School of Nuclear Science and Technology, University of South China, Hengyang (China)

Description

A lumped parameter dynamic model for U-tube steam generator of AP1000 nuclear plant was presented. A Matlab/Simulink module was established and employed to simulate the model. The results show that the presented model can well reflect the static and dynamic characteristic of U-tube steam generator. The model can be constituted the real time simulation system of AP1000 nuclear plant with other models. It also provides a theoretical analysis basis for the steam generator water level measurement, pressure measurement, and feedwater and steam flow measurement system. (authors)

Additional details

Publishing Information

Journal Title
Nuclear Electronics and Detection Technology
Journal Volume
33
Journal Issue
12
Journal Page Range
p. 1464-1468
ISSN
0258-0934

Optional Information

Notes
6 figs., 2 tabs., 8 refs.