Attenuation corrections through energy spectra analysis of whole body and partial body measurements applying gamma spectroscopy
- 1. Wuerzburg Univ. (Germany). Klinik und Poliklinik fuer Nuklearmedizin
Description
The study was carried out within the framework of activities for testing means of direct determination of radioactivity levels in the human body due to incorporated, inhomogenously distributed radionuclides. A major task was to derive the average depth of activity distributions, particularly from photon radiation at energies below 500 keV, for the purpose of making suitable attenuation corrections. The paper presents two applicable methods which yield information on the mean depths of activity distributions, obtained through additional analyses of the energy spectra. The analyses are based on measuring the dependence of intensity of the Compton radiation on the length of pathways of the photons penetrating the soft tissue, or on measuring the energy-dependent absorption effects with photons. (orig./CB)
Abstract (German)
Im Rahmen der direkten Aktivitaetsbestimmung bei inhomogener Radionukliddeposition im menschlichen Koerper mittels Ganz- oder Teilkoerpermessanlagen im klinischen Bereich oder im Strahlenschutz sollte besonders bei Photonenstrahlung mit Energien von weniger als 500 keV eine Ermittlung der mittleren Tiefe der Aktivitaetsverteilung zur Schwaechungskorrektur erfolgen. Im klinischen Umfeld ist es haeufig moeglich, zur Tiefenkorrektur die mittlere Organtiefe und damit die schwaechende Gewebsschicht mittels Ultraschall zu bestimmen. Ergaenzend hierzu werden im Folgenden zwei Methoden vorgestellt, welche Aussagen ueber die mittlere Tiefe von Aktivitaetsverteilungen durch Gewinnung von Zusatzinformationen aus dem Energiespektrum im Rahmen von gamma-spektroskopischen Personenmessungen ermoeglichen. Dazu werden einerseits die Abhaengigkeit der Intensitaet der Comptonstrahlung von der Laenge der Wegstrecke von Photonen durch Weichgewebe und andererseits energieabhaengige Absorptionseffekte bei Photonen als Grundlage herangezogen. (orig.)
Files
Additional details
Additional titles
- Original title (German)
- Schwaechungskorrektur bei gammaspektroskopischen Ganz- und Teilkoerpermessungen durch Analyse der Energiespektren
Publishing Information
- Imprint Title
- High-resolution gamma spectroscopy with whole-body and partial-body counters. Experience, recommendations. Report
- Imprint Pagination
- 102 p.
- Journal Page Range
- p. 77-91
- Report number
- VKTA--47
Conference
- Title
- High-resolution gamma spectroscopy with whole-body and partial-body counters - Experience, recommendations
- Original Conference Title
- Arbeitstagung: Hochaufloesende Gamma-Spektrometrie an Ganz- und Teilkoerperzaehlern - Erfahrungen, Empfehlungen
- Acronym
- Working meeting
- Dates
- 5-6 Dec 1996
- Place
- Dresden (Germany)
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 29042645
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- ACCURACY; CALIBRATION; COMPTON EFFECT; ENERGY SPECTRA; GAMMA SPECTROSCOPY; HIGH-PURITY GE DETECTORS; IODINE 131; PERSONNEL MONITORING; PHANTOMS; THYROID; WHOLE-BODY COUNTING
- Descriptors DEC
- BASIC INTERACTIONS; BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; BODY; COUNTING TECHNIQUES; DAYS LIVING RADIOISOTOPES; ELASTIC SCATTERING; ELECTROMAGNETIC INTERACTIONS; ENDOCRINE GLANDS; GE SEMICONDUCTOR DETECTORS; GLANDS; INTERACTIONS; INTERMEDIATE MASS NUCLEI; IODINE ISOTOPES; ISOTOPES; MEASURING INSTRUMENTS; MOCKUP; MONITORING; NUCLEI; ODD-EVEN NUCLEI; ORGANS; RADIATION DETECTORS; RADIATION MONITORING; RADIOISOTOPES; SCATTERING; SEMICONDUCTOR DETECTORS; SPECTRA; SPECTROSCOPY; STRUCTURAL MODELS
Optional Information
- Notes
- Imprint:Hochaufloesende Gamma-Spektrometrie an Ganz- und Teilkoerperzaehlern. Erfahrungen, Empfehlungen. Bericht