The Fog Excess Water Index (FEWI) method of fog prediction has been verified by the use of data obtained at the Dresden cooling pond during 1976 and 1977 and by a reanalysis of observations made in conjunction with a study of cooling pond simulators during 1974. For applications in which the method is applied to measurements or estimates of bulk water temperature, a critical value of about 0.7 mb appears to be most appropriate. The present analyses confirm the earlier finding that wind speed plays little part in determining the susceptibility for fog generation

Files

10437344.pdf

Files (221.5 kB)

Name Size Download all
md5:3a5d69cea4431c09c3c9c96d29d78469
221.5 kB Preview Download

Additional details

Publishing Information

Imprint Title
Meteorological Effects of Thermal Energy Releases (METER) Program. Annual progress report, October 1976--September 1977
Journal Page Range
p. 59-66.