Published March 1977
| Version v1
Journal article
Error in anti-DNA antibody radioimmunoassay after gallium scanning
- 1. National Institutes of Health, Bethesda, MD
Description
Significant interference with the accurate measurement of anti-DNA antibodies occurs after gallium-67 scanning. The observed effect is dependent on the radioimmunoassay used. False-negative results are observed with a modified Farr assay whereas false-positive results are noted in the millipore filter assay. These spurious values are the result of persistent radioactivity in the patients' sera after administration of 67Ga citrate
Additional details
Identifiers
Publishing Information
- Journal Title
- Annals of Internal Medicine
- Journal Volume
- 86
- Journal Issue
- 3
- Series
- Ann. Intern. Med.
- Journal Page Range
- 309-311
- ISSN
- 0003-4819
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 8321692
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ANTIBODIES; DNA; ERRORS; GALLIUM 67; RADIOIMMUNOASSAY; SCINTISCANNING
- Descriptors DEC
- BETA DECAY RADIOISOTOPES; COUNTING TECHNIQUES; DAYS LIVING RADIOISOTOPES; DIAGNOSTIC TECHNIQUES; ELECTRON CAPTURE RADIOISOTOPES; GALLIUM ISOTOPES; INTERMEDIATE MASS NUCLEI; ISOTOPE APPLICATIONS; ISOTOPES; MEDICINE; NUCLEAR MEDICINE; NUCLEI; NUCLEIC ACIDS; ODD-EVEN NUCLEI; ORGANIC COMPOUNDS; RADIOISOTOPE SCANNING; RADIOISOTOPES; TRACER TECHNIQUES
Optional Information
- Notes