Description
The results of an investigation of x-ray CdTe detector spectrometric parameters within the temperature range from + 20 to -100 deg C are presented. Slight cooling of a detector (-50 deg C) improves significantly its energy resolution due to decreasing current noise and increasing operational potential. Gamma energy spectra of 241Am and x-ray energy spectra of Fe and Cd excited from a 109Cd source have been obtained at -40 deg C and 400 V operational potential. Lines of the x-ray spectra detected are pointed out to be appropriately resolved indicating a possibility of spectroscopy analysis of elements with Z(>=)25 atomic numbers
Additional details
Additional titles
- Original title (Russian)
- Детекторы рентгеновского излучения на основе теллурида кадмия
- Augmented title (English)
- Temperature noise
Publishing Information
- Journal Title
- At. Ehnerg.
- Journal Volume
- 42
- Journal Issue
- 5
- Series
- At. Ehnerg.
- Journal Page Range
- 391-394
INIS
- Country of Publication
- USSR
- Country of Input or Organization
- USSR
- INIS RN
- 9376642
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- CDTE SEMICONDUCTOR DETECTORS; DATA; ELECTRIC CONDUCTIVITY; ENERGY DEPENDENCE; ENERGY RESOLUTION; LOW TEMPERATURE; MEDIUM TEMPERATURE; TEMPERATURE DEPENDENCE; TEMPERATURE NOISE; X RADIATION; X-RAY SPECTRA
- Descriptors DEC
- ELECTRICAL PROPERTIES; ELECTROMAGNETIC RADIATION; INFORMATION; IONIZING RADIATIONS; MEASURING INSTRUMENTS; NOISE; PHYSICAL PROPERTIES; RADIATION DETECTORS; RADIATIONS; RESOLUTION; SEMICONDUCTOR DETECTORS; SPECTRA
Optional Information
- Notes
- For English translation see the journal Sov. At. Energy.