Published September 2002 | Version v1
Journal article

Radiation exposure in nuclear medicine: real-time measurement

  • 1. Beaujon Hospital, Clichy (France). Dept. of Nuclear Medicine
  • 2. X. Bichat University, Paris (France). Biophysics Lab.

Description

French regulations have introduced the use of electronic dosimeters for personnel monitoring of workers. In order to evaluate the exposure from diagnostic procedures to nuclear medicine staff, individual whole-body doses were measured daily with electronic (digital) personal dosimeters during 20 consecutive weeks and correlated with the work load of each day. Personal doses remained always below 20 mu Sv/d under normal working conditions. Radiation exposure levels were highest to tech staff, nurses and stretcher-bearers. The extrapolated annual cumulative doses for all staff remained less than 10% of the maximum legal limit for exposed workers (2 mSv/yr). Electronic dosimeters are not technically justified for routine survey of staff. The high sensitivity and immediate reading of electronic semiconductor dosimeters may become very useful for exposure control under risky working conditions. It may become an important help for optimising radiation protection. (author)

Additional details

Publishing Information

Journal Title
Brazilian Archives of Biology and Technology
Journal Volume
45
Journal Issue
special issue
Journal Page Range
p. 111-114
ISSN
1516-8913

Conference

Title
International meeting on advances in nuclear medicine and in radiopharmaceuticals
Dates
26-28 Sep 2002
Place
Cabo Frio, RJ (Brazil)

INIS

Optional Information

Notes
8 refs., 2 tabs., 2 graphs