Purpose: To determine the correlation between dose rate and Tl in blood at Gd-enhanced MR angiography (MRA). Material and Methods: A test dose of contrast agent was used to calculate the time delay between injection and arrival in the abdominal aorta. The dose rate was expressed as ml x kg b.w.-1 x s-1. The correlation between dose rate and Tl was determined by varying the dose rate while keeping the scanning and infusion times constant. The signal intensity in the abdominal aorta was measured during the first pass of Gd and compared with markers of known Tl values. Results: A correlation between dose rate and Tl in blood was obtained. Conclusion: A Gd dose rate of 0.01 ml x kg b.w.-1 x s-1 gives a Tl in blood of 100 ms. This can be used to calculate the optimal pulse sequence for contrast-enhanced MRA. (orig.)