Published March 2016 | Version v1
Journal article

L X-ray satellite effects on the determination of photon emission intensities of radionuclides

Description

L X-ray satellites are usually not considered during the fitting procedure of L X-ray spectra obtained with semiconductor detectors. Based on a high energy resolution spectrum of X-rays of 241Am obtained with a metallic magnetic calorimeter, it has been demonstrated that satellites are intense with respect to their parent diagram line. In addition, it has been shown that the presence of satellites involves significant systematic errors on the determined photon intensities when they are ignored in the spectrum processing. - Highlights: • 241Am L X-ray spectrum measured with ultra-high energy resolution. • Cryogenic detector with a FWHM energy resolution of 25.5 eV. • Evidence of intense L X-ray satellites in 241Am. • Systematic errors on individual L X-ray emission intensities due to satellites. • Semiconductor spectrometers are suitable for measurements of L X-ray groups.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.apradiso.2015.11.100

Additional details

Identifiers

DOI
10.1016/j.apradiso.2015.11.100;
PII
S0969-8043(15)30328-6;

Publishing Information

Journal Title
Applied Radiation and Isotopes
Journal Volume
109
Journal Page Range
p. 570-575
ISSN
0969-8043
CODEN
ARISEF

Conference

Title
20. international conference on radionuclide metrology and its applications
Dates
8-11 Jun 2015
Place
Vienna (Austria)

Optional Information

Copyright
Copyright (c) 2015 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.