Beta planar source quality assurance with the Fricke xylenol gel dosimeter
Creators
- 1. Departamento de Física da Universidade de São Paulo, Av. Bandeirantes 3900, Bloco, P1-14040-901 Ribeirão Preto, SP (Brazil)
- 2. Instituto Federal de Educação, Ciência e Tecnologia de Goiás, Av. Universitária, s/n, Vale das Goiabeiras, CEP: 75400-000, Inhumas, Goiás (Brazil)
- 3. Instituto de Radioterapia e Megavoltagem de Ribeirão Preto-IRMEV, Rua Sete de Setembro 1150, CEP 14010-180 Ribeirão Preto, SP (Brazil)
Description
Beta therapy is employed in post surgery to treat lesions such as pterygia, keloid and glioblastoma. The beta source most used for these purposes is 90/90Y, whose quality assurance is a challenge, because the detectors currently used for this evaluation do not satisfy the spatial resolution, the effective atomic number and the tissue equivalent conditions. The Fricke xylenol gel (FXG) has been used in several applications in radiotherapy due to its better characteristics. This dosimeter is associated with the Fe(II) to Fe(III) oxidation, post ionizing irradiation, being the final Fe(III) concentration linearly depended on the absorbed dose. The goal of this present work is to show that the FXG, with atomic effective number (Zeff) of 7.75 and high resolution (<1 mm), accomplishes quality assurance for rectangular and square planar 90Sr/90Y sources. In order to demonstrate the quality assurance, calibration curves, percentage depth dose and beam profile from exposed FXG samples were analyzed and from these results, we demonstrate the potential use of the FXG dosimeter for beta source quality control
Availability note (English)
Available from http://dx.doi.org/10.1016/j.radphyschem.2013.08.014Additional details
Identifiers
- DOI
- 10.1016/j.radphyschem.2013.08.014;
- PII
- S0969-806X(13)00499-4;
Publishing Information
- Journal Title
- Radiation Physics and Chemistry (1993)
- Journal Volume
- 96
- Journal Page Range
- p. 56-59
- ISSN
- 0969-806X
- CODEN
- RPCHDM
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 45113023
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Descriptors DEI
- ABSORBED RADIATION DOSES; BEAM PROFILES; BETA SOURCES; DEPTH DOSE DISTRIBUTIONS; DOSEMETERS; GELS; GLIOMAS; QUALITY ASSURANCE; QUALITY CONTROL; RADIOTHERAPY; SPATIAL RESOLUTION; STRONTIUM 90; YTTRIUM 90
- Descriptors DEC
- ALKALINE EARTH ISOTOPES; BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; COLLOIDS; CONTROL; DAYS LIVING RADIOISOTOPES; DISEASES; DISPERSIONS; DOSES; EVEN-EVEN NUCLEI; HOURS LIVING RADIOISOTOPES; INTERMEDIATE MASS NUCLEI; ISOMERIC TRANSITION ISOTOPES; ISOTOPES; MEASURING INSTRUMENTS; MEDICINE; NEOPLASMS; NERVOUS SYSTEM DISEASES; NUCLEAR MEDICINE; NUCLEI; ODD-ODD NUCLEI; PARTICLE SOURCES; RADIATION DOSE DISTRIBUTIONS; RADIATION DOSES; RADIATION SOURCES; RADIOISOTOPES; RADIOLOGY; RESOLUTION; SPATIAL DOSE DISTRIBUTIONS; STRONTIUM ISOTOPES; THERAPY; YEARS LIVING RADIOISOTOPES; YTTRIUM ISOTOPES
Optional Information
- Copyright
- Copyright (c) 2013 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.