An imaging evaluation of the simultaneously integrated boost breast radiotherapy technique
- 1. Department of Radiation Oncology, Royal Prince Alfred Hospital, Camperdown, New South Wales (Australia)
Description
To evaluate in-field megavoltage (MV) imaging of simultaneously integrated boost (SIB) breast fields to determine its feasibility in treatment verification for the SIB breast radiotherapy technique, and to assess whether the current-imaging protocol and treatment margins are sufficient. For nine patients undergoing SIB breast radiotherapy, in-field MV images of the SIB fields were acquired on days that regular treatment verification imaging was performed. The in-field images were matched offline according to the scar wire on digitally reconstructed radiographs. The offline image correction results were then applied to a margin recipe formula to calculate safe margins that account for random and systematic uncertainties in the position of the boost volume when an offline correction protocol has been applied. After offline assessment of the acquired images, 96% were within the tolerance set in the current department-imaging protocol. Retrospectively performing the maximum position deviations on the Eclipse™ treatment planning system demonstrated that the clinical target volume (CTV) boost received a minimum dose difference of 0.4% and a maximum dose difference of 1.4% less than planned. Furthermore, applying our results to the Van Herk margin formula to ensure that 90% of patients receive 95% of the prescribed dose, the calculated CTV margins were comparable to the current departmental procedure used. Based on the in-field boost images acquired and the feasible application of these results to the margin formula the current CTV-planning target volume margins used are appropriate for the accurate treatment of the SIB boost volume without additional imaging
Availability note (English)
Available from http://dx.doi.org/10.1002/jmrs.117; Available from http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4592674Additional details
Identifiers
Publishing Information
- Journal Title
- Journal of Medical Radiation Sciences (Print)
- Journal Volume
- 62
- Journal Issue
- 3
- Journal Page Range
- p. 198-203
- ISSN
- 2051-3895
INIS
- Country of Publication
- Australia
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 46126045
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BIOMEDICAL RADIOGRAPHY; CHARGES; CORRECTIONS; DOSES; IMAGES; MAMMARY GLANDS; PATIENTS; PROFITS; RADIOTHERAPY; VERIFICATION
- Descriptors DEC
- BODY; DIAGNOSTIC TECHNIQUES; GLANDS; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; THERAPY
Optional Information
- Copyright
- Copyright (c) 2015 The Authors. Journal of Medical Radiation Sciences published by Wiley Publishing Asia Pty Ltd on behalf of Australian Institute of Radiography and New Zealand Institute of Medical Radiation Technology.
- Notes
- PMCID: PMC4592674; PMID: 26451242; OAI: oai:pubmedcentral.nih.gov:4592674