Tube-to-tubesheet joint test. Volume 2. Final report

Description

The PWR steam generator tube to tubesheet crevice test program was formulated to develop flushing procedures for removing concentrated chemical solutions from partially rolled (deep) tubesheet crevices and to investigate the characteristics of various tube to tubesheet joint crevice configurations with regard to the initiation of concentration processes. The crevice flushing testing indicated that significant fractions of a concentrated sodium hydroxide solution could be transported out of a full depth, unpacked tubesheet crevice by heating and then depressurizing the contents of the crevice. Based upon testing of both packed and unpacked crevices, the most effective flushing procedure was found to utilize the primary coolant system as the heat source, an initial crevice temperature of about 3000F, a nitrogen overpressure in the steam generator, and alternating rapid and slow depressurizations

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS, PC A14/MF A01; 1 as DE83902312.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Additional titles

Augmented title (English)
PWR

Publishing Information

Imprint Pagination
306 p.
Report number
EPRI-NP--3013-Vol.2