Advanced Gas Cooled Reactor Materials Program. Reducing helium impurity depletion in HTGR materials testing
Description
Moisture depletion in HTGR materials testing rigs has been empirically studied in the GE High Temperature Reactor Materials Testing Laboratory (HTRMTL). Tests have shown that increased helium flow rates and reduction in reactive (oxidizable) surface area are effective means of reducing depletion. Further, a portion of the depletion has been shown to be due to the presence of free C released by the dissociation of CH4. This depletion component can be reduced by reducing the helium residence time (increasing the helium flow rate) or by reducing the CH4 concentration in the test gas. Equipment modifications to reduce depletion have been developed, tested, and in most cases implemented in the HTRMTL to date. These include increasing the Helium Loop No. 1 pumping capacity, conversion of metallic retorts and radiation shields to alumina, isolation of thermocouple probes from the test gas by alumina thermowells, and substitution of non-reactive Mo-TZM for reactive metallic structural components
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS, PC A03/MF A01; 1 as DE84016619.
Files
Additional details
Publishing Information
- Imprint Pagination
- 33 p.
- Report number
- DOE/ET/34034--107
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 16031373
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- COOLANTS; HELIUM; HTGR TYPE REACTORS; HUMIDITY; MATERIALS TESTING; METHANE; SIMULATION; TESTING
- Descriptors DEC
- ALKANES; ELEMENTS; GAS COOLED REACTORS; GRAPHITE MODERATED REACTORS; HYDROCARBONS; NONMETALS; ORGANIC COMPOUNDS; RARE GASES; REACTORS