Published December 1984 | Version v1
Report Open

The effects of rotating field frequency on the rotamak configuration

Description

Experiments have been undertaken at three rotating field frequencies, 1.0, 1.85 and 3.5 MHz, to determine the effect upon the rotamak configuration and the driven toroidal current. Toroidal current has been driven at all three rotating field frequencies for each of the gases studied. The results indicate that the 1.0 MHz frequency chosen for the rotating field in the high power AAEC rotamak experiments appears to be satisfactory

Availability note (English)

MF available from INIS under the Report Number.

Files

17018047.pdf

Files (232.2 kB)

Name Size Download all
md5:f839dd3f8df285dcfdbd934b3c4e5843
232.2 kB Preview Download

Additional details

Publishing Information

ISBN
0 642 59811 8
Imprint Pagination
17 p.
Report number
AAEC/E--603

INIS

Country of Publication
Australia
Country of Input or Organization
Australia
INIS RN
17018047
Subject category
S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
Resource subtype / Literary indicator
Numerical Data
Descriptors DEI
ARGON; COMPACT TORUS; CYCLOTRON FREQUENCY; ELECTRIC CURRENTS; EXPERIMENTAL DATA; HYDROGEN; MAGNETIC FIELD CONFIGURATIONS; MAGNETIC FIELDS; MHZ RANGE 01-100; PLASMA; ROTATION; TOKAMAK DEVICES
Descriptors DEC
CLOSED PLASMA DEVICES; CURRENTS; DATA; ELEMENTS; FREQUENCY RANGE; INFORMATION; MHZ RANGE; NONMETALS; NUMERICAL DATA; RARE GASES; THERMONUCLEAR DEVICES; TORI