Published July 2003
| Version v1
Journal article
The use of image simulation on estimating indicators for digital radiograph system
Creators
- 1. Tsinghua Univ., Beijing (China). Inst. of Nuclear Technology
Description
CI (Contrast Indicator), IQI (Image Quality Indicator) and SP (Steel Penetration) are the important indicators in the digital radiograph system. The estimating of them takes an important status in the system performance design. At present the estimate method is lack of the support from experiment and the result is distinct from the measurement. This paper uses the computer simulation method to estimate the indicators of the 60Co container inspection system and gets a very good result
Additional details
Publishing Information
- Journal Title
- Nuclear Electronics and Detection Technology
- Journal Volume
- 23
- Journal Issue
- 4
- Journal Page Range
- p. 320, 321-323
- ISSN
- 0258-0934
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 35053577
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- COBALT 60; COMPUTERIZED SIMULATION; CONTAINERS; DIGITAL SYSTEMS; IMAGES; INDUSTRIAL RADIOGRAPHY; INSPECTION; SPECIFICATIONS; USES
- Descriptors DEC
- BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; COBALT ISOTOPES; INTERMEDIATE MASS NUCLEI; INTERNAL CONVERSION RADIOISOTOPES; ISOMERIC TRANSITION ISOTOPES; ISOTOPES; MATERIALS TESTING; MINUTES LIVING RADIOISOTOPES; NONDESTRUCTIVE TESTING; NUCLEI; ODD-ODD NUCLEI; RADIOISOTOPES; SIMULATION; TESTING; YEARS LIVING RADIOISOTOPES