An automatic input/output test experience of FPGA-based logic controller with I/O stimulator - 282

  • 1. Instrumentation and Control / Human Factors Division, Korea Atomic Energy Research Institute, 989-111 Daedeok-daero, Yuseong-gu, Daejeon, Republic of Korea 305-353 (Korea, Republic of)

Description

This paper describes an automatic testing approach instead of a traditional manual test for an FPGA-based Logic Controller (FLC). It mainly describes an automatic testing of FLC using an I/O stimulator with the initiated manual action. The FLC was developed by Doosan Heavy Industry and KAERI in S. Korea. We also developed a test-bed like I/O stimulator for a burning test based on the operational scenario. Signal sources from the I/O stimulator contain an analog input, an analog output, a digital input and a digital output, a programmable power supply, an RS232C serial interface, and a dual port Ethernet interface. LabVIEW Programming was used for the automatic testing. The FLC consists of a general processor module (FPM-01), a complex processor module (FPM-02), analog input modules (FAI-01), analog output modules (FAO-01), digital input modules (FDI-01), digital output modules (FDO-01), a data link module (FDL-01), and a network module (FNW-01). Among these, in this paper, automatic digital I/O testing and automatic analog I/O testing are described. In addition, for the accuracy of the automatic testing, two graphic recorders are used. One is the output results of general processor based testing, and the other is the output results of complex processor based testing. These are different company products. Redundancy recording was found in the test results. The test results were synchronized internally with the existing I/O stimulator and externally with two graphic recorders. Calibrations of all of the equipment were made before the system testing. Before the testing started, a test plan and the test procedure were set up in advance, and we performed test scenario-based automatic functional testing for the FLC as the qualification process. It can be several executed depending on the scenario and conditional parameters of the test. For validation of the accuracy and reliability in our automated test, manual testing was also performed. Manual tests were conducted in two ways. The first one was a manual test using Fluke 754 and Fluke 715. The other one was using embedded manual features of the I/O stimulator. By performing the automatic input and output testing using the I/O stimulator, the time and expense of FLC testing can be reduced significantly compared with a conventional manual test. We rechecked the automatic test results using Fluke754 manually. (authors)

Additional details

Publishing Information

Publisher
American Nuclear Society - ANS
Imprint Place
La Grange Park, IL (United States)
Imprint Pagination
6 p.

Conference

Title
10. International Conference on Nuclear Plant Instrumentation, Control, and Human-Machine Interface Technologies
Acronym
NPIC and HIMIT 2017
Dates
11-15 Jun 2017
Place
San Francisco, CA (United States)

INIS

Country of Publication
United States
Country of Input or Organization
France
INIS RN
52075764
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ACCURACY; KAERI; PERFORMANCE; PROGRAMMING; REDUNDANCY; RELIABILITY; REPUBLIC OF KOREA; SIGNALS; VALIDATION
Descriptors DEC
ASIA; DEVELOPING COUNTRIES; KOREAN ORGANIZATIONS; NATIONAL ORGANIZATIONS; TESTING

Optional Information

Notes
14 refs.; available from American Nuclear Society - ANS, 555 North Kensington Avenue, La Grange Park, IL 60526 (US)