Published 1991 | Version v1
Book

A decade of radiological and shielding experience at the fast flux test facility

Creators

  • 1. Westinghouse Hanford Co., Richland, WA (United States)

Description

This paper reports on which the Fast Flux Test Facility (FFTF) which has operated for almost a decade after first going critical during February 1980. Based on about 2,000 effective full-power days of operation, it is concluded that radiological safety can be achieved in large liquid metal-cooled fast reactors. The collective dose equivalents received by operating personnel are significantly lower than those received at commercial light water reactors. No major contamination problems have been encountered in operating and maintaining the plant, and release of radioactive materials to the environment has been well below acceptable limits. All shields have performed satisfactorily and in agreement with design calculations. The experience derived from the design, construction, and operation of the FFTF should be of inestimable value in supporting future development of liquid metal reactors

Additional details

Publishing Information

Publisher
American Nuclear Society.
Imprint Place
La Grange Park, IL (United States)
ISBN
0-89448-157-6
Imprint Title
Proceedings of LMR
Imprint Pagination
348 p.
Journal Page Range
p. 75-83.

Conference

Title
American Nuclear Society (ANS) winter meeting.
Dates
11-16 Nov 1990.
Place
Washington, DC (United States).

Optional Information

Secondary number(s)
CONF-901101--.