Published May 2011 | Version v1
Miscellaneous

Design of Accelerator Emergency Stop System for the Proton Accelerator Research Center of PEFP

  • 1. Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

Description

Proton Engineering Frontier Project (PEFP) of Korea Atomic Energy Research Institute was established as one of the 21st Centuty Frotier Research and Development Programs by Ministry of Science and Technology, is aiming to develop the 100 MeV, 20mA proton linear accelerator as a user's facility for scientific and industrial utilization. When using high power 100MeV proton linear accelerator, a high radiation field is formed in the surrounded area, the surrounded substances are radiation-activated. For this reason, this paper describes the design of Accelerator Emergency Stop System, which in Proton Accelerator Research Center(PARC) of PEFP protects personnel from radiation hazards and the machine operation in case unsafe conditions occur

Part of:
Proceedings of the KNS spring meeting

Additional details

Publishing Information

Publisher
KNS
Imprint Place
Daejeon (Korea, Republic of)
Imprint Title
Proceedings of the KNS spring meeting
Imprint Pagination
[1 CD-ROM]
Journal Page Range
[2 p.]

Conference

Title
2011 spring meeting of the KNS
Dates
26-27 May 2011
Place
Taebaek (Korea, Republic of)

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
42099304
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
ACCIDENTS; DESIGN; LINEAR ACCELERATORS; RADIATIONS
Descriptors DEC
ACCELERATORS

Optional Information

Notes
3 refs, 3 figs, 1 tab