Published 1990
| Version v1
Book
Is the quality of routine chest CT improved by changing to a high-resolution algorithm
Creators
Description
This paper assesses the effect of changing to a high-resolution reconstruction algorithm on image and diagnostic quality of standard chest CT and to compare this with fine-section, high-resolution CT. Forty patients with a variety of pulmonary diseases underwent chest CT with a Somatom Plus scanner (Siemens). Representative 10-mm sections were reconstructed with both standard and high-resolution algorithms and compared with 2-mm high-resolution sections at the same levels by three radiologists blinded to the reconstruction and clinical data
Additional details
Publishing Information
- Publisher
- Radiological Society of North America Inc.
- Imprint Place
- Oak Brook, IL (United States)
- Imprint Title
- Seventy sixth scientific assembly and annual meeting of the Radiological Society of North America
- Imprint Pagination
- 331 p.
- Journal Page Range
- p. 295-296.
Conference
- Title
- 76. scientific assembly and annual meeting of the Radiological Society of North America.
- Dates
- 25-30 Nov 1990.
- Place
- Chicago, IL (United States).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 23043361
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- ALGORITHMS; CHEST; COMPUTERIZED TOMOGRAPHY; DIAGNOSIS; IMAGE PROCESSING
- Descriptors DEC
- BODY; BODY AREAS; TOMOGRAPHY
Optional Information
- Secondary number(s)
- CONF-901103--.