Published December 1, 2011 | Version v1
Journal article

Optimal Normal Tissue Sparing in Craniospinal Axis Irradiation Using IMRT With Daily Intrafractionally Modulated Junction(s)

  • 1. Department of Radiation Oncology, Radboud University Nijmegen Medical Centre, Nijmegen (Netherlands)
  • 2. Department of Pediatric Oncology, Radboud University Nijmegen Medical Centre, Nijmegen (Netherlands)
  • 3. Department of Neurosurgery, Radboud University Nijmegen Medical Centre, Nijmegen (Netherlands)

Description

Purpose: To develop a treatment technique for craniospinal irradiation using intensity-modulated radiotherapy (IMRT) with improved dose homogeneity at the field junction(s), increased target volume conformity, and minimized dose to the organs at risk (OARs). Methods and Materials: Five patients with high-risk medulloblastoma underwent CT simulation in supine position. For each patient, an IMRT plan with daily intrafractionally modulated junction(s) was generated, as well as a treatment plan based on conventional three-dimensional planning (3DCRT). A dose of 39.6 Gy in 22 daily fractions of 1.8 Gy was prescribed. Dose–volume parameters for target volumes and OARs were compared for the two techniques. Results: The maximum dose with IMRT was <107% in all patients. V<95 and V>107 were <1 cm3 for IMRT compared with 3–9 cm3 for the craniospinal and 26–43 cm3 for the spinal–spinal junction with 3DCRT. These observations corresponded with a lower homogeneity index and a higher conformity index for the spinal planning target volume with IMRT. IMRT provided considerable sparing of acute and late reacting tissues. V75 for the esophagus, gastroesophageal junction, and intestine was 81%, 81%, and 22% with 3DCRT versus 5%, 0%, and 1% with IMRT, respectively. V75 for the heart and thyroid was 42% and 32% vs. 0% with IMRT. Conclusion: IMRT with daily intrafractionally modulated junction results in a superior target coverage and junction homogeneity compared with 3DCRT. A significant dose reduction can be obtained for acute as well as late-reacting tissues.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.ijrobp.2010.07.1987

Additional details

Identifiers

DOI
10.1016/j.ijrobp.2010.07.1987;
PII
S0360-3016(10)03034-8;

Publishing Information

Journal Title
International Journal of Radiation Oncology, Biology and Physics
Journal Volume
81
Journal Issue
5
Journal Page Range
p. 1405-1414
ISSN
0360-3016
CODEN
IOBPD3