Published May 2011 | Version v1
Journal article

Toward an individualized target motion management for IMRT of cervical cancer based on model-predicted cervix-uterus shape and position

  • 1. Department of Radiation Oncology, Erasmus-MC Daniel den Hoed Cancer Center, Rotterdam (Netherlands)
  • 2. Programme of Diagnostic Imaging and Radiotherapy, University Kebangsaan Malaysia (Malaysia)

Description

Background and Purpose: To design and evaluate a 3D patient-specific model to predict the cervix-uterus shape and position. Methods and Materials: For 13 patients lying in prone position, 10 variable bladder filling CT-scans were acquired, 5 at planning and 5 after 40 Gy. The delineated cervix-uterus volumes in 2-5 pre-treatment CT-scans were used to generate patient-specific models that predict the cervix-uterus geometry by bladder volume. Model predictions were compared to delineations, excluding those used for model construction. The prediction error was quantified by the margin required around the predicted volumes to accommodate 95% of the delineated volume and by the predicted-to-delineated surface distance. Results: The prediction margin was significantly smaller (average 50%) than the margin encompassing the cervix-uterus motion. The prediction margin could be decreased (from 7 to 5 mm at planning and from 10 to 8 mm after 40 Gy) by increasing (from 2 to 5) the number of CT-scans used for the model construction. Conclusion: For most patients, even with a model based on only two CT-scans, the prediction error was well below the margin encompassing the cervix-uterus motion. The described approach could be used to create prior to treatment, an individualized treatment strategy.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.radonc.2011.03.013

Additional details

Identifiers

DOI
10.1016/j.radonc.2011.03.013;
PII
S0167-8140(11)00168-X;

Publishing Information

Journal Title
Radiotherapy and Oncology
Journal Volume
99
Journal Issue
2
Journal Page Range
p. 240-245
ISSN
0167-8140
CODEN
RAONDT

INIS

Country of Publication
Ireland
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
43064831
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
BLADDER; CAT SCANNING; FORECASTING; NEOPLASMS; PATIENTS; PROFITS; RADIOTHERAPY; SHAPE; SIMULATION; UTERUS
Descriptors DEC
BODY; COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC TECHNIQUES; DISEASES; FEMALE GENITALS; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; THERAPY; TOMOGRAPHY; URINARY TRACT