Published October 1983 | Version v1
Journal article

Removing uranium from drinking water by metal hydroxides and anion-exchange resin

  • 1. Oak Ridge National Laboratories, Oak Ridge, TN

Description

Results of bench-scale testing on uranium removal from a natural water that was chosen as a good representative of uranium-bearing waters indicated that conventional coagulant and lime softening treatment removes more than 85 percent of dissolved uranium (83 μg U/L) when an optimum pH and dosage were provided. A strong base anion-exchange column is a recommended option for the treatment of private well waters containing uranium at higher than desirable levels

Additional details

Publishing Information

Journal Title
J. Am. Water Works Assoc.
Journal Volume
75
Journal Issue
10
Series
J. Am. Water Works Assoc.
Journal Page Range
536-540
ISSN