Published September 2006 | Version v1
Journal article

Determination of the isomeric ratio in fission fragment 135Xe by using the inert gaseous flow

  • 1. Institute of Physics and Electronics, VAST, Ha Noi (Viet Nam)
  • 2. Flerov Laboratory of Nuclear Reaction, JINR, Dubna (Russian Federation)

Description

In this work we present a method for determination of the Isomeric Ratio of Fission Fragment using the inert gaseous flow. The fission fragment in gaseous state is separated from fission camera by the inert gaseous flow and collected in a cryostat filled by liquid nitrogen and then are measured with high energy resolution semiconductor detector. The isomeric ratio is calculated on the basis of a system of equations describing irradiation, cooling and measurement processes. (author)

Additional details

Publishing Information

Journal Title
Communications in Physics
Journal Volume
16
Journal Issue
3
Series
Published by the Vietnamese Academy of Science and Technology
Journal Page Range
p. 177-183
ISSN
0868-3166

Optional Information

Notes
4 figs., 8 refs.