Published August 1, 1994
| Version v1
Journal article
Log-ratio technique for beam position monitor systems
Creators
- 1. Superconducting Super Collider Laboratory, 2550 Beckleymeade Ave., Dallas, TX 75237 (United States)
Description
Recent progress in the development of a beam position monitor system (BPM), based on the log-ratio technique, is described in this paper. A complete electronic analysis is presented, showing linearity, dynamic range, noise, RF burst response, and temperature dependence. A calibration technique has been developed, which corrects the errors due to mismatched channels and electronics drift. This technique is particularly effective because of the log-ratio property for beam position monitoring. ((orig.))
Additional details
Publishing Information
- Journal Title
- Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
- Journal Volume
- 346
- Journal Issue
- 3
- Journal Page Range
- p. 426-432.
- ISSN
- 0168-9002
- CODEN
- NIMAER
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- Netherlands
- INIS RN
- 26011597
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- BACKGROUND NOISE; BEAM MONITORING; BEAM MONITORS; BEAM POSITION; CALIBRATION; ELECTRON DRIFT; ELECTRONIC CIRCUITS; ERRORS; FLUCTUATIONS; RESPONSE FUNCTIONS; RF SYSTEMS; TEMPERATURE DEPENDENCE; TEMPERATURE RANGE 0273-0400 K
- Descriptors DEC
- FUNCTIONS; MEASURING INSTRUMENTS; MONITORING; MONITORS; NOISE; TEMPERATURE RANGE; VARIATIONS