Published June 1987 | Version v1
Report Open

Calculation of MCPR [minimum critical power ratio] for BWR transients using the BNL plant analyzer

Description

The critical power ratio (CPR) is used for determining the thermal limits of boiling water reactors. In this study, critical power ratios for a series of transients run on the Brookhaven Plant Analyzer (BPA) [1] have been calculated. The transients include nominal base case simulations, simulations with variations in relief valve setpoints and the number of failed feedwater heaters, simulations at the 100% power, 75% flow point on the extended load line of the MEOD, and a simulation with partial feedwater heating. The plant represented with the BPA is a BWR/4 rated at 3293 MW with a 6.38 m (251'') vessel. Data were obtained by the Plant Analyzer Development Group at BNL from a variety of sources describing the Browns Ferry Plant

Availability note (English)

Available from NTIS, PC A02/MF A01 as DE87012109.

Files

19023473.pdf

Files (87.5 kB)

Name Size Download all
md5:a0e263e0a5d3d1533f847b890cc2ef5e
87.5 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
6 p.
Report number
BNL-NUREG--39959

Conference

Title
Joint meeting of the American Nuclear Society and the Atomic Industrial Forum.
Dates
15-19 Nov 1987.
Place
Los Angeles, CA (USA).

Optional Information

Secondary number(s)
CONF-871101--36.