Description
Collimators are essential components of industrial radiography set up as it provides radiation safety to persons involved in the radiography work. A collimator with optimum design features also helps in reducing the scattered radiation which in turn results in radiographs having better sensitivity. This papers describes the salient design features of the tungsten collimators developed by the BRIT, for industrial radiography. (author)
Additional details
Publishing Information
- Journal Title
- Radiation Protection and Environment
- Journal Volume
- 24
- Journal Issue
- 1-2
- Journal Page Range
- p. 326-328
- ISSN
- 0972-0464
Conference
- Title
- 25. international conference on radiation protection measurements and dosimetry: current practices and future trends
- Acronym
- IARP-IC.2K1
- Dates
- 20-23 Feb 2001
- Place
- Mumbai (India)
INIS
- Country of Publication
- India
- Country of Input or Organization
- India
- INIS RN
- 32029544
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- COLLIMATORS; INDUSTRIAL RADIOGRAPHY; OCCUPATIONAL SAFETY; RADIATION PROTECTION; SPECIFICATIONS; TUNGSTEN ALLOYS
- Descriptors DEC
- ALLOYS; MATERIALS TESTING; NONDESTRUCTIVE TESTING; SAFETY; TESTING; TRANSITION ELEMENT ALLOYS
Optional Information
- Notes
- 1 fig.