Published March 1, 2004 | Version v1
Journal article

Performance of aerogel as Cherenkov radiator

Description

Aerogel with index of refraction around 1.03 has been studied as Cherenkov radiator in a test at CERN PS using a π- and a mixed π+/p beam of momenta between 6 and 10 GeV/c. The Cherenkov photons were detected by means of four large HPD tubes designed and constructed at CERN. Results on the photoelectron yield, the Cherenkov angle and its resolution, and the π/p separation are obtained. The performances measured demonstrate that a RICH with aerogel is a viable detector for experiments with high multiplicity of particles in the final state

Additional details

Identifiers

DOI
10.1016/j.nima.2003.09.062;
PII
S0168900203028687;

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
519
Journal Issue
3
Journal Page Range
p. 493-507