Published 1987 | Version v1
Book

The application of the signal flow graph method to charged-particle optics: The formula derivation of a three-sector isotope separator

  • 1. Institute of Atomic Energy, Academia Sinica, Beijing

Description

A brief introduction of the Signal Flow Graph (SFG) Method is given. The application of it to charged-particle optics (CPO) is described. The method has the advantages of simplicity, visualisation and computerisation. An example of the application of SFG is given for the design of a three-sector electromagnetic isotope separator

Additional details

Publishing Information

Publisher
Elsevier Science Pub. Co. Inc.
Imprint Place
New York, NY (USA)
Imprint Title
Electromagnetic isotope separators and techniques related to their applications
Journal Page Range
p. 28-33.

Conference

Title
11. international conference on electromagnetic isotope separators and techniques related to their applications.
Dates
18-22 Aug 1986.
Place
Los Alamos, NM (USA).

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
19023069
Subject category
S07: ISOTOPES AND RADIATION SOURCES; S99: GENERAL AND MISCELLANEOUS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ALGORITHMS; CHARGED PARTICLES; COMPUTER GRAPHICS; ELECTROMAG ISOTOPE SEPARATORS; IMAGE PROCESSING; ISOTOPE SEPARATION PLANTS; MONITORING; OPTICS; PLANNING; SIGNAL CONDITIONING; SPECIFICATIONS
Descriptors DEC
INDUSTRIAL PLANTS; NUCLEAR FACILITIES