Published November 1993
| Version v1
Miscellaneous
Testing Romania's reactor-1 building
Creators
- 1. AECL ANSALDO Project Management Team, Cernavoda, (Romania)
Description
As a part of general inaugural inspection and testing program, the Cernavoda unit 1 containment structure's structural integrity has already been proved last year through pressure test. These test methods, instrumentation and results are summarized in this briefing. (Author)
Availability note (English)
Available from Romanian Nuclear Energy Association AREN, Polytechnic University of Bucharest.Additional details
Publishing Information
- Publisher
- Romanian Nuclear Energy Association 'AREN' in cooperation with Polytechnic University of Bucharest.
- Imprint Place
- Bucharest (Romania)
- Imprint Title
- SIEN '93 - International Symposium on Nuclear Energy
- Imprint Pagination
- 85 p.
- Journal Page Range
- v. 2 p. 63-67.
Conference
- Title
- SIEN '93 - International Symposium on Nuclear Energy.
- Dates
- 3-4 Dec 1993.
- Place
- Bucharest (Romania).
INIS
- Country of Publication
- Romania
- Country of Input or Organization
- Romania
- INIS RN
- 25052721
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- BAROMETERS; BUILDINGS; CERNAVODA-1 REACTOR; DISPLACEMENT GAGES; LEAK TESTING; MEASURING METHODS; OPTICAL SYSTEMS; PERFORMANCE TESTING; PRESSURIZATION; ROMANIA; STRAIN GAGES; THERMOMETERS
- Descriptors DEC
- CANDU TYPE REACTORS; DEVELOPING COUNTRIES; EASTERN EUROPE; EUROPE; HEAVY WATER COOLED REACTORS; HEAVY WATER MODERATED REACTORS; MEASURING INSTRUMENTS; NATURAL URANIUM REACTORS; PHWR TYPE REACTORS; POWER REACTORS; PRESSURE GAGES; PRESSURE TUBE REACTORS; REACTORS; TESTING; THERMAL REACTORS