Published January 1998 | Version v1
Journal article

Effect of recirculation of 99mTc-Sn colloid in estimating mean transit time of soft-tissue vascular anomalies by direct puncture scintigraphy. A simulation analysis

  • 1. Tokyo Univ. (Japan). Faculty of Medicine

Description

We have reported direct puncture scintigraphy, a novel method to estimate mean transit time (MTT) of soft-tissue vascular anomaly. In the examination, 99mTc-Sn colloid is infused percutaneously into the lesion, and MTT is calculated using the time-activity curve for the lesion. Recirculation of 99mTc-Sn colloid is neglected in computing MTT, and this may cause error. The aim of this study was to assess this error by simulation analysis. Data simulating direct puncture scintigraphy were produced for lesions with various blood volumes and various blood flows, considering recirculation and blood clearance of 99mTc-Sn colloid, and MTT was estimated by the same method used in the patient examination. Although MTT was overestimated in large lesions with intermediate or long MTT, the error was small except in extremely large lesions. It was suggested that recirculation of 99mTc-Sn colloid does not cause a serious problem in the clinical use of direct puncture scintigraphy. (author)

Additional details

Publishing Information

Journal Title
Radiation Medicine
Journal Volume
16
Journal Issue
1
Journal Page Range
p. 1-5
ISSN
0288-2043
CODEN
RAMEER

Optional Information

Notes
This record replaces 29037525